Nicolet iS50 FTIR Spectrometer overview
The Thermo Scientific™ Nicolet iS50 is a modular FTIR spectrometer for materials identification and characterization. It combines a full-size sample compartment, OMNIC software and Touch Point controls. With the appropriate optics and modules, laboratories can expand a standard mid-IR bench to cover far-IR through visible wavelengths and add complementary techniques such as Raman.

350–7,800 cm⁻¹
Standard spectral range
< 0.09 cm⁻¹
Mid-IR optical resolution
Touch Point
One-touch instrument setup
Key features
Touch Point controls select the beam path, optical components and sampling module for the chosen method. OMNIC can combine spectra, analyses and images in a single group file and generate reports. The full-size sample compartment supports Thermo Scientific Smart Accessories and a range of standard accessories.
Optional modules and accessories
Configure the Nicolet iS50 for direct ATR sampling, automated spectral range changes, Raman mapping, NIR sampling or coupled TGA-IR and GC-IR analysis.
Built-in diamond ATR
Measure powders, liquids, gels and pastes in the mid- and far-IR. The built-in sampling station leaves the main sample compartment available for other experiments.

Automated Beamsplitter Exchanger (ABX)
Use Touch Point controls to change beamsplitters for near-, mid- and far-IR workflows while maintaining the instrument seal, desiccation or purge.

Raman module
Install the Raman accessory in the sample compartment to complement material identification, map samples and screen well plates.

NIR module
Use the integrating sphere for bulk samples or the fiber optic connection for in situ measurements of solids and liquids.

TGA-IR accessory
Characterize gases released during thermogravimetric analysis with Mercury TGA software. ATR can also examine the starting material and residue.

GC-IR module
Pair gas chromatography with infrared detection for qualitative, isomer-specific analysis using OMNIC Mercury GC software.

Technical specifications
The standard Nicolet iS50 covers 350–7,800 cm⁻¹ and achieves mid-IR optical resolution better than 0.09 cm⁻¹. The available spectral range depends on the optical configuration.
| Specification | Nicolet iS50 |
|---|---|
| Spectral range, standard optics | 350–7,800 cm⁻¹ |
| Spectral range, CsI optics | 200–6,400 cm⁻¹ |
| Spectral range, multi-range optics | 10–27,000 cm⁻¹ |
| Optical resolution, mid-IR | Better than 0.09 cm⁻¹ |
| IR source | Polaris™ long-life mid-IR source (standard) |
| NIR/visible source | Tungsten-halogen (optional) |
| Detector | DLaTGS (standard) |
| Optical coatings | Gold (standard), aluminum (optional) |
| Validation | Validation and attenuation wheels (standard). ValPro™ system validation software (optional). |
| Software and interface | OMNIC™ software (standard), USB 2.0 |
| Base dimensions (W × D × H) | 62.6 × 69.8 × 27.6 cm |
| Base weight | 60 kg |
| Reference laser | He-Ne (Class I laser product) |
See the Thermo Scientific Nicolet iS50 specification sheet for configuration details and performance test conditions.
Applications
The Nicolet iS50 supports raw-material identification, formulation studies and QA/QC across polymer, pharmaceutical, food and general analytical laboratories. Select the sampling method based on the material and the question the analysis needs to answer.
Polymers and rubber
identify raw materials and study blends, morphology and reaction kinetics.
Pharmaceuticals
examine formulations and polymorphs and develop QA/QC methods.
Pigments, paints and inks
investigate inorganic fillers and additives in organic formulations.
Food, flavors and oils
analyze moisture, fat, proteins and seed oils or distinguish isomeric flavors and fragrances.
Forensics
use complementary infrared and Raman measurements or GC-IR to distinguish isomeric compounds.
Infrared microscopy
An optional infrared microscope extends the workstation to analysis of small structures.

Frequently asked questions
The base instrument supports mid-IR measurements. The appropriate optics and sampling accessories depend on the spectral range, sample form and analytical method.
Can the Nicolet iS50 measure far-IR and near-IR?
Yes. Optional optics extend coverage beyond standard mid-IR. The ABX can automate beamsplitter changes for workflows spanning far-, mid- and near-IR.
What samples can I run with the built-in ATR?
The optional diamond ATR handles powders, liquids, gels and pastes with minimal setup. Its separate sampling station leaves the main sample compartment available.
Can ATR and Raman be installed at the same time?
Yes. The optional diamond ATR has a dedicated sampling station, and the optional Raman module mounts in the main sample compartment.
What is available for performance verification?
A validation wheel is standard. Thermo Scientific also lists ValPro system validation software and 21 CFR Part 11 compliance tools as options for regulated workflows.
Request a quote
Contact BECTHAI for a quote on the Nicolet iS50. Share your sample types, required spectral range and planned techniques so the team can discuss the appropriate configuration.